Drill Out Bottom Hole
Drill Bottom Hole
With the transformer hanging vertically, mark the bottom hole. Slide the transformer aside and now drill the hole for the bottom anchor sleeve. Put your masonry anchor and screw together, put them in the hole and secure it down with the screwdriver. With the bottom screw in place, you can now secure down the top screw for the transformer.
Begin Connecting
Begin connecting your system. For a simple connection process, use a clamp connect transformer, which uses levers instead of the screw mechanism to clamp to the wires. Start by connecting your transformer to your main runs. This is done by placing one strand of wire in the com terminal and the other in a terminal marked either 12 volt or 15 volt. The 12 volt tap is for shorter wire runs with fewer fixtures while the 15 volt tap is for longer runs that draw more power. Wire exiting the transformer should be protected with conduit until it reaches the ground.